Part Number Hot Search : 
MC74HC B431LBK3 45984 P4840 C18F44 AMC71 307C1545 36766
Product Description
Full Text Search
 

To Download RPD-6011 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  specification model rpd-60a dc voltage rated current current range rated power output setup, rise time hold up time (typ.) voltage range frequency range efficiency (typ.) ac current (typ.) input inrush current (typ.) leakage current safety standards harmonic current ems immunity working temp. working humidity storage temp., humidity temp. coefficient vibration mtbf dimension others note packing overload over voltage 5v 5a 0.5 ~ 5.5a 49w 53.9w 80mvp-p +3,-2% 0.5% 1.5% 200ms, 15ms/230vac 200ms, 15ms/115vac at full load 70ms/230vac 14ms/115vac at full load 90 ~ 264vac 127 ~ 370vdc 47 ~ 63hz ch1: 5.75 ~ 6.75v 78% 1.1a/115vac 0.7 a/230vac cold start 60a/230vac 30a/115vac 115 ~ 150% rated output power -20 ~ +65 (refer to output load derating curve) 20 ~ 90% rh non-condensing -40 ~ +85 , 10 ~ 95% rh 0.03%/ (0 ~ 45 ) 10 ~ 500hz, 2g 10min./1cycle, period for 60min. each along x, y, z axes 677.8khrs min. mil-hdbk-217f (25 ) 101.6*50.8*29mm (l*w*h) 0.15kg; 96pcs/15.4kg/0.89cuft 60w dual output medical type r p d - 6 0 s e r i e s withstand voltage isolation resistance environment safety & emc (note 5) protection emi conduction & radiation 1. all parameters not specially mentioned are measured at 230vac input, r ated load and 25 of ambient temperature. 2. ripple & noise are measured at 20mhz of bandwidth by using a 12" twisted pair- wire terminated with a 0.1uf & 47uf parallel capacitor. 3. tolerance : includes set up tolerance, line regulation and load regula tion. 4. 33% duty cycle maximum within every 30 seconds. average output power sho uld not exceed the rated power. 5. the power supply is considered a component which will be installed into a f inal equipment. the final equipment must be re-confirmed that it still me ets emc directives. 6. length of set up time is measured at cold first start. turning on/off the powe r supply may lead to increase of the set up time. 7. heat sink hs1,hs2 can not be shorted. for guidance on how to perform these emc tests, please refer to ?emi testing of c omponent power supplies.? (as available on http://www.meanwell.com) ripple & noise (max.) note.2 voltage tolerance note.3 features : protection type : hiccup mode, recovers automatically after fault co ndition is removed protection type : shut down o/p voltage, re-power on to recover rpd-60b 12v ch2 24v ch2 5v ch1 2a 1.5a 3.5a 0.1 ~ 2.2a 0.1 ~ 1.65a 0.5 ~ 3.85a 53.5w 58.85w 80mvp-p 100mvp-p 80mvp-p 6.0% +8,-4% 1.0% 2.0% 2.0% 1.0% +3,-2% 0.5% 1.5% 82% line regulation load regulation ch1 output number 4"x2" miniature size universal ac input/full range low leakage current<200ua protections: short circuit / over load / over voltage cooling by free air convection ul60601-1/iec60601-1/en60601-1 medical safety approved fixed switch frequency at 100khz 3 years warranty ul60950-1/iec60950-1/en60950-1 ite safety approved peak load(10sec.) note.4 file name:rpd-60-spec 2011-03-31 ul60950-1, tuv en60950-1, ul60601-1, tuv en60601-1, iec60601- 1 approved compliance to en55011(cispr11),en55022 (cispr22) class b compliance to en61000-3-2,-3 compliance to en61000-4-2,3,4,5,6,8,11; env50204, en55024, e n60601-1-2, en61204-3, medical level, criteria a i/p-o/p:4kvac i/p-fg:1.5kvac o/p-fg:1.5kvac i/p-o/p, i/p-fg, o/p-fg:100m ohms / 500vdc / 25 / 70% rh for earth <200ua/264vac, for patient <100ua/264vac en60601-1iec60601-1
mechanical specification file name:rpd-60-spec 2011-03-31 block diagram circuit detection o.l.p. emi filter rectifiers & filter filter filter & & rectifiers rectifiers +v1 v2 com i/p fg control o.v.p. output derating vs input voltage input voltage (vac) 60hz 90 100 95 120 115 160 140 200 180 240 220 264 load (%) ta=25 90 100 80 70 60 50 40 unit:mm fosc : 100khz (horizontal) 65 derating curve power switching ac input connector (cn1) : jst b3p-vh or equivalent pin no. 12 3 assignment ac/n no pin ac/l mating housing jst vhr jst svh-21t-p1.1 or equivalent or equivalent terminal 3 14 25 6 cn2 4- 3.3 101.6 50.8 95.25 cn1 fs1 fs2 2 3 1 44.45 3.175 3.175 ac fuse t2.5/250v ac fuse t2.5/250v 29 3 max. hs1 hs2 hs1,hs2 can not be shorted dc output connector (cn2) : jst b6p-vh or equivalent pin no. 1,2 3,4 56 assignment v1 v2 com nc mating housing jst vhr or equivalent terminal jst svh-21t-p1.1 or equivalent ambient temperature ( ) load (%) -20 0 20 10 30 40 20 40 80 60 100 60 50 70 60w dual output medical type r p d - 6 0 s e r i e s


▲Up To Search▲   

 
Price & Availability of RPD-6011

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X